| Huawei Technologies Co., Ltd RH2288 V2 | SPECpower_ssj2008 = 4,786 overall ssj_ops/watt | ||||
| Test Sponsor: | Huawei Technologies Co., Ltd | SPEC License #: | 3175 | Test Method: | Single Node |
| Tested By: | Huawei Technologies Co., Ltd | Test Location: | Shenzhen, Guangdong, China | Test Date: | Oct 12, 2012 |
| Hardware Availability: | Aug-2012 | Software Availability: | Jun-2012 | Publication: | Oct 31, 2012 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 235 | 23.1 |
| Calibration 2 | 236 | 23.0 |
| Calibration 3 | 236 | 22.9 |
| 100% | 236 | 22.8 |
| 90% | 225 | 22.7 |
| 80% | 211 | 22.6 |
| 70% | 194 | 22.5 |
| 60% | 174 | 22.5 |
| 50% | 151 | 22.4 |
| 40% | 127 | 22.3 |
| 30% | 107 | 22.3 |
| 20% | 90.2 | 22.2 |
| 10% | 76.1 | 22.2 |
| Active Idle | 66.8 | 22.2 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Meters and Instruments Corporation |
| Model: | WT210 |
| Serial Number: | 91K630156 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Metrology Institute: | CNAS (China National Accreditation Service for Conformity Assessment) |
| Accredited by: | Calibration and Testing Center of CEPREI |
| Calibration Label: | "2GB12006186-0010" |
| Date of Calibration: | 30-Jul-2012 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.1-1271fb18-20110728 |
| Setup Description: | none |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Temperature@lert |
| Model: | TM-STD30 |
| Driver Version: | 3.1.0.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | Use a 2 meters USB extension cable to connect to the controller. And placed in front the main airflow inlet of the SUT less than 50mm. |
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 221 | 300.0 | 1.09 | 2.0 | 0.975 | 235 | 0.4% |
| Calibration 2 | 221 | 300.0 | 1.09 | 2.0 | 0.975 | 236 | 0.4% |
| Calibration 3 | 221 | 300.0 | 1.10 | 2.0 | 0.975 | 236 | 0.4% |
| 100% | 222 | 300.0 | 1.09 | 2.0 | 0.975 | 236 | 0.4% |
| 90% | 220 | 300.0 | 1.05 | 2.0 | 0.973 | 225 | 0.4% |
| 80% | 221 | 300.0 | 0.987 | 2.0 | 0.969 | 211 | 0.4% |
| 70% | 221 | 300.0 | 0.915 | 1.0 | 0.961 | 194 | 0.3% |
| 60% | 222 | 300.0 | 0.821 | 1.0 | 0.953 | 174 | 0.3% |
| 50% | 222 | 300.0 | 0.717 | 1.0 | 0.949 | 151 | 0.4% |
| 40% | 222 | 300.0 | 0.608 | 1.0 | 0.943 | 127 | 0.4% |
| 30% | 223 | 300.0 | 0.512 | 1.0 | 0.938 | 107 | 0.5% |
| 20% | 223 | 300.0 | 0.437 | 1.0 | 0.928 | 90.2 | 0.5% |
| 10% | 223 | 300.0 | 0.375 | 1.0 | 0.912 | 76.1 | 0.6% |
| Active Idle | 223 | 300.0 | 0.334 | 0.5 | 0.898 | 66.8 | 0.4% |