SPECstorage™ Solution 2020_eda_blended ResultCopyright © 2016-2022 Standard Performance Evaluation Corporation |
Nettrix | SPECstorage Solution 2020_eda_blended = 240 Job_Sets |
---|---|
Nettrix with 6 NVMe Storage Server | Overall Response Time = 0.14 msec |
|
Nettrix with 6 NVMe Storage Server | |
---|---|
Tested by | Nettrix | Hardware Available | Apr 2021 | Software Available | Apr 2021 | Date Tested | Dec 2021 | License Number | 6138 | Licensee Locations | Beijing, China |
Nettrix R620 G40 makes full use of computing ,storage and network resources in a limited space. It can flexibly allocate resources according to business needs to achieve excellent cost performance and energy consumption ratio. It is widely applicable to various industries such as Internet, finance, communication and transportation to meet the needs of different business models.
Item No | Qty | Type | Vendor | Model/Name | Description |
---|---|---|---|---|---|
1 | 1 | Storage Server | Nettrix | R620 G40 | The current R620 G40 is - 2 Intel Xeon 40 core processor, total 1 TiB memory, and dual socket MB - using NFSv4 protocol over a 100GbE NIC. R620 G40 server provides IO/s from 6 file systems. The R620 G40 server uses a dual socket processor, 1 PCIe Gen3.1 SSD, 6 PCIe Gen4 SSDs. R620 G40 is running RHEL8.3 on PCIe Gen3.1 SSD using NFSv4 and 1 100GbE Ethernet networking. |
2 | 1 | Ethernet Switch | NVIDIA(Mellanox) | SN2410 | Mellanox Spectrum®-based 48-port 25GbE + 8-port 100GbE Open Ethernet Platform. |
3 | 1 | Clients Server | Nettrix | R620 G40 | The current R620 G40 is - 2 Intel Xeon 40 core processor, total 512 GiB memory, and dual socket MB - using NFSv4 protocol over a 100GbE NIC. The R620 G40 server uses a dual socket processor, 1 960GB SATA SSD for OS, 1 1.0 TB PCIe Gen3.1 SSD for storage. R620 G40 is running ESXi 6.7 OS on SATA SSD using NFSv4 and 1 100GbE Ethernet networking. The R620 G40 server contains 8 virtual machines, each VM has: 16 vCPUs, 50GB memory, 100GB storage and a 100GB network port provided by the SR-IOV function. |
4 | 1 | Disk | Samsung | MZ7KH960 | 960GB 2.5" SATA SSD installed in clients server (R620 G40) for ESXI OS. |
5 | 2 | Disk | Intel | SSDPE2KX010T8 | 1TB PCIe Gen3.1 NVMe disk: 1 of 2 installed in storage server (R620 G40) for RHEL8.3 OS, 1 of 2 installed in clients server (R620 G40) used to store VMs. |
6 | 6 | Disk | Samsung | MZQL27T60 | 7.68TB PCIe Gen4 NVMe installed in storage server (R620 G40). |
7 | 2 | Ethernet Card | NVIDIA(Mellanox) | MCX623436AN-CDAB | ConnectX®-6 Dx EN adapter card, 100GbE, OCP3.0, With Host Management, Dual-port QSFP56, PCIe 4.0 x16, No Crypto, Thumbscrew (Pull Tab) Bracket.1 of 2 installed in storage server (R620 G40), 1 of 2 installed in clients server (R620 G40). |
Item No | Component | Type | Name and Version | Description |
---|---|---|---|---|
1 | Storage Server | Linux | RHEL 8.3 | Storage Server Operating System. |
2 | Clients Server | ESXi Server | ESXi-6.7.0 | The OS version is ESXi-6.7.0-20190802001-standard. |
3 | Clients | Linux | RHEL 8.3 | The VMware ESXi 6.7 server was configured to run 8 VM's running RHEL 8.3 OS. |
Storage Server | Parameter Name | Value | Description |
---|---|---|
MTU | 1500 | Default value of OS | Clients Server | Parameter Name | Value | Description |
SR-IOV | Enabled | Network card's SR-IOV function in BIOS is set to Enabled | Clients | Parameter Name | Value | Description |
MTU | 1500 | Default value of OS |
Each VM has a 100GB network port provided by SR-IOV function, and VM use default vswitch and default 1Gb vNIC.
N/A | Parameter Name | Value | Description |
---|---|---|
N/A | N/A | N/A |
NFSv4 is in sync mode.
None
Item No | Description | Data Protection | Stable Storage | Qty |
---|---|---|---|---|
1 | 960GB for clients server ESXI OS | None | Yes | 1 |
2 | 1.0TB to store VMs date OS | None | Yes | 1 |
3 | 1.0TB for storage server OS | None | Yes | 1 |
4 | 6x7.68TB for storage server IOs | None | Yes | 6 |
Number of Filesystems | 6 | Total Capacity | 46.08 TiB | Filesystem Type | xfs |
---|
The file systems were created on the storage server using all default parameters.
The 46.08TiB was equally allocated across all 6 filesystems.
Item No | Transport Type | Number of Ports Used | Notes |
---|---|---|---|
1 | 100GbE | 2 | Storage server and clients server both connect to the 100Gb link |
None
Item No | Switch Name | Switch Type | Total Port Count | Used Port Count | Notes |
---|---|---|---|---|---|
1 | SN2410 | Ethernet Switch | 56 | 2 | 8x 100GbE and 48x 25GbE ports are available. 2x 100GbE ports are used. |
Item No | Qty | Type | Location | Description | Processing Function |
---|---|---|---|---|---|
1 | 2 | CPU | Storage Server | Intel(R) Xeon(R) Platinum 8380 CPU @ 2.30GHz, hyperthreading enabled | Storage Server |
2 | 80 | vCPU | Clients Server | Dual Intel(R) Xeon(R) Platinum 8380 CPU @ 2.30GHz each with 40 cores | Clients Server |
Clients server and storage server have the same CPU, However, in order to ensure the normal operation of the clients server's ESXi OS, Each VM has 10 vCPUs only.
Description | Size in GiB | Number of Instances | Nonvolatile | Total GiB |
---|---|---|---|---|
System memory in storage server | 32 | 32 | NV | 1024 |
System memory in clients server | 32 | 16 | NV | 512 | Grand Total Memory Gibibytes | 1536 |
None
The storage server shares NFS in sync mode, so all NFS operations by clients are immediately committed to disk without passing through memory. The entire SUT is protected with redundant power supplies, both storage server and clients server.
None
Use the spectre-meltdown-checker tool to check the storage server, and the results are shown as follows: 1.CVE-2017-5753 aka 'Spectre Variant 1, bounds check bypass'>STATUS: NOT VULNERABLE (Mitigation: Load fences, __user pointer sanitization) 2.CVE-2017-5715 aka 'Spectre Variant 2, branch target injection'>STATUS: NOT VULNERABLE (Enhanced IBRS + IBPB are mitigating the vulnerability) 3.CVE-2017-5754 aka 'Variant 3, Meltdown, rogue data cache load'>STATUS: NOT VULNERABLE (your CPU vender reported your CPU model as not vulnerable)
All the clients mounted 6 file systems from the storage server as follows: server:/storage/nvme1 /nfs/nvme1 nfs defaults 0 0 server:/storage/nvme2 /nfs/nvme2 nfs defaults 0 0 server:/storage/nvme3 /nfs/nvme3 nfs defaults 0 0 server:/storage/nvme4 /nfs/nvme4 nfs defaults 0 0 server:/storage/nvme5 /nfs/nvme5 mfs defaults 0 0 server:/storage/nvme6 /nfs/nvme6 mfs defaults 0 0
None
None
Generated on Wed Feb 23 14:20:12 2022 by SpecReport
Copyright © 2016-2022 Standard Performance Evaluation Corporation