SPECstorage™ Solution 2020_eda_blended ResultCopyright © 2016-2024 Standard Performance Evaluation Corporation |
NetApp Inc. | SPECstorage Solution 2020_eda_blended = 8100 Job_Sets |
---|---|
NetApp 8-node AFF A90 with FlexGroup | Overall Response Time = 1.17 msec |
|
NetApp 8-node AFF A90 with FlexGroup | |
---|---|
Tested by | NetApp Inc. | Hardware Available | June 2024 | Software Available | June 2024 | Date Tested | June 2024 | License Number | 33 | Licensee Locations | Sunnyvale, CA USA |
Designed and built for customers seeking a storage solution for the high
demands of enterprise applications, the NetApp high-end flagship all-flash AFF
A90 delivers unrivaled performance, superior resilience, and best-in-class data
management across the hybrid cloud. With an end-to-end NVMe architecture
supporting the latest NVMe SSDs, and both NVMe/FC and NVMe/TCP network
protocols, it provides over 27% performance increase over its predecessor with
ultra-low latency. Powered by ONTAP data management software, it supports
non-disruptive scale-out to a cluster of 24 nodes.
ONTAP is designed
for massive scaling in a single namespace to over 20PB with over 400 billion
files while evenly spreading the performance across the cluster. This makes the
AFF A90 a great system for engineering and design applications as well as
DevOps. It is particularly well-suited for chip development and software builds
that are typically high file-count environments with high data and meta-data
traffic.
Item No | Qty | Type | Vendor | Model/Name | Description |
---|---|---|---|---|---|
1 | 4 | Storage System | NetApp | AFF A90 Flash System (HA Pair, Active-Active Dual Controller) | A single NetApp AFF A90 system is a chassis with 2 controllers. A set of 2 controllers comprises a High-Availability (HA) Pair. The words "controller" and "node" are used interchangeably in this document. One internal FS4483 disk shelf is direct-connected to the AFF A90 controllers, with 48 SSDs per disk shelf. Each AFF A90 HA Pair includes 2048GB of ECC memory, 128GB of NVRAM, 18 PCIe expansion slots and a set of included I/O ports: Included CoreBundle, Data Protection Bundle and Security and Compliance bundle which includes All Protocols, SnapRestore, SnapMirror, FlexClone, Autonomous Ransomware Protection, SnapCenter and SnapLock. Only the NFS protocol license is active in the test which is available in the Core Bundle. |
2 | 16 | Network Interface Card | NetApp | 2-Port 100GbE X50130A | 1 card in slot 1 and 1 card in slot 7 of each controller; 4 cards per HA pair; used for cluster connections. |
3 | 16 | Network Interface Card | NetApp | 2-Port 100GbE X50131A | 1 card in slot 6 and 1 card in slot 11 of each controller; 4 cards per HA pair; used for data connections to clients as part of bonded LACP 4x100 GbE. |
4 | 4 | Internal Disk Shelf | NetApp | FS4483 (48-SSD Disk Shelf) | Disk shelf with capacity to hold up to 48 x 2.5" drives. |
5 | 144 | Solid-State Drive | NetApp | 1.92TB NVMe SSD X4016A | NVMe Solid-State Drives (NVMe SSDs) installed in FS4483 disk shelf, 48 per shelf |
6 | 48 | Solid-State Drive | NetApp | 3.8TB NVMe SSD X4011A | NVMe Solid-State Drives (NVMe SSDs) installed in FS4483 disk shelf, 48 per shelf |
7 | 9 | Network Interface Card | Mellanox Technologies | ConnectX-5 MCX516A-CCAT | 2-port 100 GbE NIC, one installed per Lenovo SR650 V2 client. lspci output: Mellanox Technologies MT27800 Family [ConnectX-5] |
8 | 4 | Network Interface Card | Mellanox Technologies | ConnectX-6 CX653106A-ECAT | 2-port 100 GbE NIC, one installed per Lenovo SR650 V3 client. lspci output: Mellanox Technologies MT28908 Family [ConnectX-6] |
9 | 2 | Switch | Cisco | Cisco Nexus 9336C-FX2 | Used for Ethernet data connections between clients and storage systems. Only the ports used for this test are listed in this report. See the 'Transport Configuration - Physical' section for connectivity details. |
10 | 2 | Switch | Cisco | Cisco Nexus 9336C-FX2 | Used for Ethernet connections of AFF A90 storage cluster network. Only the ports used for this test are listed in this report. See the 'Transport Configuration - Physical' section for connectivity details. |
11 | 9 | Client | Lenovo | Lenovo ThinkSystem SR650 V2 | Lenovo ThinkSystem SR650 V2 clients. System Board machine type is 7Z73CTO1WW, PCIe Riser part number R2SH13N01D7. Each client also contains 2 Intel Xeon Gold 6330 CPU @ 2.00GHz with 28 cores, 8 DDR4 3200MHz 128GB DIMMs, 240GB M.2 SATA SSD part number SSS7A23276, and a 240G M.2 SATA SSD part number SSDSCKJB240G7. All 8 clients are used to generate the workload, 1 is used as Prime Client. |
12 | 4 | Client | Lenovo | Lenovo ThinkSystem SR650 V3 | Lenovo ThinkSystem SR650 V3 clients. System Board machine type is 7D76CTO1WW, PCIe Riser part number SC57A86662. Each client also contains 2 Intel Xeon Gold 5420 CPU @ 2.00GHz with 28 cores, 32 DDR5 3200MHz 32GB DIMMs, 240GB M.2 SATA SSD part number ER3-GD240. All 4 SR650 V3 clients are also used to generate the workload, in addition to the 8 SR650 V2 clients. |
Item No | Component | Type | Name and Version | Description |
---|---|---|---|---|
1 | Linux | Operating System | RHEL 9.2 (Kernel 6.5.0-rc2+) | Operating System (OS) for the 13 clients |
2 | ONTAP | Storage OS | 9.15.1RC2 | Storage Operating System |
3 | Data Switch | Operating System | 9.3(3) | Cisco switch NX-OS (system software) |
Storage | Parameter Name | Value | Description |
---|---|---|
MTU | 9000 | Jumbo Frames configured for data ports |
Data network was set up with MTU of 9000.
Clients | Parameter Name | Value | Description |
---|---|---|
rsize,wsize | 262144 | NFS mount options for data block size |
protocol | tcp | NFS mount options for protocol |
nfsvers | 3 | NFS mount options for NFS version |
nofile | 102400 | Maximum number of open files per user |
nproc | 10240 | Maximum number of processes per user |
sunrpc.tcp_slot_table_entries | 128 | sets the number of (TCP) RPC entries to pre-allocate for in-flight RPC requests |
net.core.wmem_max | 16777216 | Maximum socket send buffer size |
net.core.wmem_default | 1048576 | Default setting in bytes of the socket send buffer |
net.core.rmem_max | 16777216 | Maximum socket receive buffer size |
net.core.rmem_default | 1048576 | Default setting in bytes of the socket receive buffer |
net.ipv4.tcp_rmem | 1048576 8388608 33554432 | Minimum, default and maximum size of the TCP receive buffer |
net.ipv4.tcp_wmem | 1048576 8388608 33554432 | Minimum, default and maximum size of the TCP send buffer |
net.core.optmem_max | 4194304 | Maximum ancillary buffer size allowed per socket |
net.core.somaxconn | 65535 | Maximum tcp backlog an application can request |
net.ipv4.tcp_mem | 4096 89600 8388608 | Maximum memory in 4096-byte pages across all TCP applications. Contains minimum, pressure and maximum. |
net.ipv4.tcp_window_scaling | 1 | Enables TCP window scaling |
net.ipv4.tcp_timestamps | 0 | Turn off timestamps to reduce performance spikes related to timestamp generation |
net.ipv4.tcp_no_metrics_save | 1 | Prevent TCP from caching connection metrics on closing connections |
net.ipv4.route.flush | 1 | Flush the routing cache |
net.ipv4.tcp_low_latency | 1 | Allows TCP to make decisions to prefer lower latency instead of maximizing network throughput |
net.ipv4.ip_local_port_range | 1024 65000 | Defines the local port range that is used by TCP and UDP traffic to choose the local port. |
net.ipv4.tcp_slow_start_after_idle | 0 | Congestion window will not be timed out after an idle period |
net.core.netdev_max_backlog | 300000 | Sets maximum number of packets, queued on the input side, when the interface receives packets faster than kernel can process |
net.ipv4.tcp_sack | 0 | Disable TCP selective acknowledgements |
net.ipv4.tcp_dsack | 0 | Disable duplicate SACKs |
net.ipv4.tcp_fack | 0 | Disable forward acknowledgement |
vm.dirty_expire_centisecs | 30000 | Defines when dirty data is old enough to be eligible for writeout by the kernel flusher threads. Unit is 100ths of a second. |
vm.dirty_writeback_centisecs | 30000 | Defines a time interval between periodic wake-ups of the kernel threads responsible for writing dirty data to hard-disk. |
Tuned the necessary client parameters as shown above, for communication between
clients and storage controllers over Ethernet, to optimize data transfer and
minimize overhead.
The second M.2 SSD in each client was configured as
a dedicated swap space of 224GB.
None
Item No | Description | Data Protection | Stable Storage | Qty |
---|---|---|---|---|
1 | 1.92TB NVMe SSDs used for data and storage operating system; used to build three RAID-DP RAID groups per storage controller node in the cluster | RAID-DP | Yes | 144 |
2 | 3.8TB NVMe SSDs used for data and storage operating system; used to build three RAID-DP RAID groups per storage controller node in the cluster | RAID-DP | Yes | 48 |
3 | 1.92TB NVMe M.2 device, 1 per controller; used as boot media | none | Yes | 6 |
4 | 3.8TB NVMe M.2 device, 1 per controller; used as boot media | none | Yes | 2 |
Number of Filesystems | 1 | Total Capacity | 384TiB | Filesystem Type | NetApp FlexGroup |
---|
The single FlexGroup consumed all data volumes from all of the aggregates across all of the nodes.
The storage configuration consisted of 4 AFF A90 HA pairs (8 controller nodes
total). The two controllers in a HA pair are connected in a SFO (storage
failover) configuration. Together, all 8 controllers (configured as an HA pair)
comprise the tested AFF A90 HA cluster. Stated in the reverse, the tested AFF
A90 HA cluster consists of 4 HA Pairs, each of which consists of 2 controllers
(also referred to as nodes).
Each storage controller was connected to
its own and partner's NVMe drives in a multi-path HA configuration.
All
NVMe SSDs were in active use during the test (aside from 1 spare SSD per
shelf). In addition to the factory configured RAID Group housing its root
aggregate, each storage controller was configured with two 21+2 RAID-DP RAID
Groups. There was 1 data aggregate on each node, each of which consumed one of
the node's two 21+2 RAID-DP RAID Groups. This is (21+2 RAID-DP + 1 spare per
shelf) x 4 shelves = 192 SSDs total. 16x volumes, holding benchmark data, were
created within each aggregate. "Root aggregates" hold ONTAP operating system
related files. Note that spare (unused) drive partitions are not included in
the "storage and filesystems" table because they held no data during the
benchmark execution.
A storage virtual machine or "SVM" was created on
the cluster, spanning all storage controller nodes. Within the SVM, a single
FlexGroup volume was created using the one data aggregate on each controller. A
FlexGroup volume is a scale-out NAS single-namespace container that provides
high performance along with automatic load distribution and scalability.
Item No | Transport Type | Number of Ports Used | Notes |
---|---|---|---|
1 | 100GbE | 45 | For the client-to-storage network, the AFF A90 Cluster used a total of 32x 100 GbE connections from storage to the switch, communicating via NFSv3 over TCP/IP to 12 clients, via 1x 100GbE connection to the switch for each client. MTU=9000 was used for data switch ports. |
2 | 100GbE | 16 | The Cluster Interconnect network is connected via 100 GbE to a Cisco 9336C-FX2 switch, with 4 connections to each HA pair.. |
Each AFF A90 HA Pair used 4x 100 GbE bonded LACP ports for data transport connectivity to clients (through a Cisco 9336C-FX2 switch), Item 1 above. Each of the clients driving workload used 1x 100GbE ports for data transport. All ports on the Item 1 network utilized MTU=9000. The Cluster Interconnect network, Item 2 above, also utilized MTU=9000. All interfaces associated with dataflow are visible to all other interfaces associated with dataflow.
Item No | Switch Name | Switch Type | Total Port Count | Used Port Count | Notes |
---|---|---|---|---|---|
1 | Cisco Nexus 9336C-FX2 | 100GbE | 36 | 23 | 6 client-side 100 GbE data connections, 1 port per client; 4 storage-side bonded LACP 4x 100 GbE data connections (half of A90 nodes on each data switch), 1 port per prime client, 4 per A90 node. Only the ports on the Cisco Nexus 9336C-FX2 used for the solution under test are included in the total port count. |
2 | Cisco Nexus 9336C-FX2 | 100GbE | 36 | 22 | 6 client-side 100 GbE data connections, 1 port per client; 4 storage-side bonded LACP 4x 100 GbE data connections (half of A90 nodes on each data switch), 4 per A90 node. Only the ports on the Cisco Nexus 9336C-FX2 used for the solution under test are included in the total port count. |
3 | Cisco Nexus 9336C-FX2 | 100GbE | 36 | 8 | 1 ports per A90 node, for Cluster Interconnect. |
4 | Cisco Nexus 9336C-FX2 | 100GbE | 36 | 8 | 1 ports per A90 node, for Cluster Interconnect. |
Item No | Qty | Type | Location | Description | Processing Function |
---|---|---|---|---|---|
1 | 16 | CPU | Storage Controller | Intel Xeon Gold 6438N | NFS, TCP/IP, RAID and Storage Controller functions |
2 | 18 | CPU | Lenovo SR650 V2 Client | Intel Xeon Gold 6330 | NFS Client, Linux OS |
3 | 8 | CPU | Lenovo SR650 V3 Client | Intel Xeon Gold 5420 | NFS Client, Linux OS |
Each of the 8 NetApp AFF A90 Storage Controllers contains 2 Intel Xeon Gold 6438N processors with 64 cores each; 2.20 GHz, hyperthreading enabled. Each of the 9 Lenovo SR650 V2 clients contains 2 Intel Xeon Gold 6330 processors with 28 cores at 2.00 GHz, and each of the 4 Lenovo SR650 V3 clients contains 2 Intel Xeon Gold 5420 processors with 28 cores at 2.00GHz. All 13 clients have hyperthreading enabled.
Description | Size in GiB | Number of Instances | Nonvolatile | Total GiB |
---|---|---|---|---|
Main Memory for NetApp AFF A90 HA Pair | 2048 | 4 | V | 8192 |
NVDIMM (NVRAM) Memory for NetApp AFF A90 HA pair | 128 | 4 | NV | 512 |
Memory for each of 13 clients | 1024 | 13 | V | 13312 | Grand Total Memory Gibibytes | 22016 |
Each storage controller has main memory that is used for the operating system and caching filesystem data. Each controller also has NVRAM; See "Stable Storage" for more information.
The AFF A90 utilizes non-volatile battery-backed memory (NVRAM) for write caching. When a file-modifying operation is processed by the filesystem (WAFL) it is written to system memory and journaled into a non-volatile memory region backed by the NVRAM. This memory region is often referred to as the WAFL NVLog (non-volatile log). The NVLog is mirrored between nodes in an HA pair and protects the filesystem from any SPOF (single-point-of-failure) until the data is de-staged to disk via a WAFL consistency point (CP). In the event of an abrupt failure, data which was committed to the NVLog but has not yet reached its final destination (disk) is read back from the NVLog and subsequently written to disk via a CP.
All clients accessed the FlexGroup from all the available network
interfaces.
Unlike a general-purpose operating system, ONTAP does not
provide mechanisms for non-administrative users to run third-party code. Due to
this behavior, ONTAP is not affected by either the Spectre or Meltdown
vulnerabilities. The same is true of all ONTAP variants including both ONTAP
running on FAS/AFF hardware as well as virtualized ONTAP products such as ONTAP
Select and ONTAP Cloud. In addition, FAS/AFF BIOS firmware does not provide a
mechanism to run arbitrary code and thus is not susceptible to either the
Spectre or Meltdown attacks. More information is available from
https://security.netapp.com/advisory/ntap-20180104-0001/.
None of the
components used to perform the test were patched with Spectre or Meltdown
patches (CVE-2017-5754,CVE-2017-5753,CVE-2017-5715).
ONTAP Storage Efficiency techniques including inline compression and inline deduplication were enabled by default, and were active during this test. Standard data protection features, including background RAID and media error scrubbing, software validated RAID checksum, and double disk failure protection via double parity RAID (RAID-DP) were enabled during the test.
Please reference the configuration diagram. 12 clients were used to generate the workload; 1 client acted as Prime Client to control the 12 workload clients. Each client used one 100 GbE connection, through a Cisco Nexus 9336C-FX2 switch. Each storage HA pair had 8x 100 GbE connections to the data switch. The filesystem consisted of one ONTAP FlexGroup. The clients mounted the FlexGroup volume as an NFSv3 filesystem. The ONTAP cluster provided access to the FlexGroup volume on every 100 GbE port connected to the data switch (32 ports total). Each of the 8 cluster nodes had 1 Logical Interfaces (LIFs) on 4x 100GbE Bonded LACP Ports, for a total of 1 LIF per node, for a total of 8 LIFs for the AFF A90 cluster. Each client created mount points across those 8 LIFs symmetrically.
There are 8 mounts per client. Example mount commands from one server are shown
below. /etc/fstab entry: 192.168.5.5:/vino_sfs2020_fg_1
/t/wle-vino-int-hi-05_a0a/vino_sfs2020_fg_1 nfs
hard,proto=tcp,vers=3,rsize=262144,wsize=262144 0 0
mount | grep sfs
192.168.5.5:/vino_sfs2020_fg_1 on /t/wle-vino-int-hi-05_a0a/vino_sfs2020_fg_1
type nfs
(rw,relatime,vers=3,rsize=262144,wsize=262144,namlen=255,hard,proto=tcp,timeo=600,retrans=2,sec=sys,mountaddr=192.168.5.5,mountvers=3,mountport=635,mountproto=tcp,local_lock=none,addr=192.168.5.5)
NetApp, Data ONTAP and WAFL are registered trademarks, FlexGroup is a trademark of NetApp, Inc. in the United States and other countries. All other trademarks belong to their respective owners and should be treated as such.
Generated on Fri Aug 16 13:01:23 2024 by SpecReport