Acer Incorporated Acer AR585 F1 SPECpower_ssj2008 = 2,562 overall ssj_ops/watt
Test Sponsor: Acer Incorporated SPEC License #: 97 Test Method: Single Node
Tested By: Acer Incorporated Test Location: Taipei, R.O.C. Test Date: Oct 27, 2010
Hardware Availability: Aug-2010 Software Availability: Dec-2009 Publication: Nov 18, 2010
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.5% 1,812,580 518 3,497
90% 90.0% 1,639,635 487 3,366
80% 79.9% 1,456,993 459 3,177
70% 69.9% 1,274,016 430 2,963
60% 60.0% 1,092,595 397 2,750
50% 49.9% 909,108 361 2,516
40% 40.1% 731,507 325 2,251
30% 30.0% 546,988 290 1,884
20% 20.0% 364,744 260 1,401
10% 9.9% 180,895 235 770
Active Idle 0 143 0
∑ssj_ops / ∑power = 2,562
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: None
Hardware
Hardware Vendor: Acer Incorporated
Model: Acer AR585 F1
Form Factor: 2U
CPU Name: AMD Opteron 6174
CPU Characteristics: 12-Core, 2.20 GHz, 12 MB L3 cache
CPU Frequency (MHz): 2200
CPU(s) Enabled: 48 cores, 4 chips, 12 cores/chip
Hardware Threads: 48 (1 / core)
CPU(s) Orderable: 2,4 chips
Primary Cache: 64 KB I + 64 KB D on chip per core
Secondary Cache: 512 KB I+D on chip per core
Tertiary Cache: 12 MB I+D on chip per chip, 6 MB shared / 6 cores
Other Cache: None
Memory Amount (GB): 32
# and size of DIMM: 16 x 2048 MB
Memory Details: 2GB 1Rx8 PC3-10600E; slots 1A, 2A, 3A and 4A populated on each processor
Power Supply Quantity and Rating (W): 1 x 1400
Power Supply Details: PWS-1K41F-1R
Disk Drive: 1 x 64GB SSD 2.5" SATA, Acer P/N:KF.0640N.001
Disk Controller: onboard SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x dual-port Intel 82576EB Gigabit Ethernet controller
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: PS2
Mouse: PS2
Monitor: Direct
Optical Drives: No
Other Hardware: None
Software
Power Management: Power save enabled in OS
Operating System (OS): Windows Server 2008, Enterprise Edition
OS Version: R2
Filesystem: NTFS
JVM Vendor: IBM Corporation
JVM Version: IBM J9 VM (build 2.4, JRE 1.6.0 IBM J9 2.4 Windows Server 2008 amd64-64 jvmwa6460sr7-20091214_49398 (JIT enabled, AOT enabled)
JVM Command-line Options: -Xmn1400m -Xms1875m -Xmx1875m -Xaggressive -Xcompressedrefs -Xgcpolicy:gencon -XlockReservation -Xnoloa -XtlhPrefetch -Xlp
JVM Affinity: start /affinity [3F,FC0,3F000,FC0000,3F000000,FC0000000,3F000000000,FC0000000000]
JVM Instances: 8
JVM Initial Heap (MB): 1875
JVM Maximum Heap (MB): 1875
JVM Address Bits: 64
Boot Firmware Version: T01
Management Firmware Version: 1.00
Workload Version: SSJ 1.2.6
Director Location: Controller
Other Software: IBM Websphere Application Server V7.0 for Windows on x86-64bit
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Acer Incorporated
Model: Gateway GR160 F1
CPU Description: Intel L5520
Memory amount (GB): 3
Software
Operating System (OS): Windows Server 2003 R2, Enterprise Edition SP2
JVM Vendor: Oracle Corporation
JVM Version: Oracle JRockit(R) (build R27.5.0-110_o-99226-1.6.0_03-20080528-1505-windows-ia32, compiled mode)
CCS Version: 1.2.4
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Electric International Pte. Ltd.
Model: WT210
Serial Number: 91H534921
Connectivity: RS232
Input Connection: Default
Calibration Institute: NML (National Measurement Laboratory, R.O.C.)
Accredited by: ETC, Taiwan
Calibration Label: 10-06-BAC-041-01
Date of Calibration: 10-Jun-2010
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.4.0-7071d9e7
Setup Description: SUT Power Supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: Watchport Virtual Port 5.0.0.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 1 cm in front of SUT main air intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 518 24.5
90% 487 23.4
80% 459 23.4
70% 430 24.1
60% 397 23.8
50% 361 23.4
40% 325 23.8
30% 290 24.6
20% 260 23.4
10% 235 23.4
Active Idle 143 24.0
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 60 Hz / 1 phase / 2 wires 23.4 132
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     1,823,052
Calibration 2     1,818,982
Calibration 3     1,825,779
ssj_ops@calibrated=1,822,381
100% 99.5% 1,822,381 1,812,580
90% 90.0% 1,640,143 1,639,635
80% 79.9% 1,457,904 1,456,993
70% 69.9% 1,275,666 1,274,016
60% 60.0% 1,093,428 1,092,595
50% 49.9% 911,190 909,108
40% 40.1% 728,952 731,507
30% 30.0% 546,714 546,988
20% 20.0% 364,476 364,744
10% 9.9% 182,238 180,895
Active Idle   0 0
Graph of results