| Huawei Technologies Co., Ltd RH2288 V2 | SPECpower_ssj2008 = 3,992 overall ssj_ops/watt | ||||
| Test Sponsor: | Huawei Technologies Co., Ltd | SPEC License #: | 3175 | Test Method: | Single Node |
| Tested By: | Huawei Technologies Co., Ltd | Test Location: | Shenzhen, Guangdong, China | Test Date: | Jun 2, 2012 |
| Hardware Availability: | Jun-2012 | Software Availability: | Dec-2011 | Publication: | Jun 28, 2012 |
| System Source: | Single Supplier | System Designation: | Server | Power Provisioning: | Line-powered |
| Target Load | Average Active Power (W) | Minimum Ambient Temperature (°C) |
|---|---|---|
| Calibration 1 | 210 | 21.3 |
| Calibration 2 | 228 | 21.2 |
| Calibration 3 | 228 | 21.4 |
| 100% | 231 | 21.4 |
| 90% | 203 | 21.6 |
| 80% | 170 | 21.4 |
| 70% | 147 | 21.4 |
| 60% | 130 | 21.4 |
| 50% | 114 | 21.5 |
| 40% | 105 | 21.5 |
| 30% | 98.0 | 22.1 |
| 20% | 89.5 | 21.9 |
| 10% | 80.1 | 21.8 |
| Active Idle | 57.0 | 22.0 |
| Power Analyzer pwr1 | |
|---|---|
| Hardware Vendor: | Yokogawa Electric International Pte. Ltd. |
| Model: | WT210 |
| Serial Number: | 91K630156 |
| Connectivity: | RS-232 |
| Input Connection: | Default |
| Metrology Institute: | CNAS (China National Accreditation Service for Conformity Assessment) |
| Accredited by: | Calibration and Testing Center of CEPREI |
| Calibration Label: | B11004997-0007 |
| Date of Calibration: | 20-Jun-2011 |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| PTDaemon Version: | 1.4.1-1271fb18-20110728 |
| Setup Description: | none |
| Temperature Sensor temp1 | |
|---|---|
| Hardware Vendor: | Temperature@lert |
| Model: | TM-STD30 |
| Driver Version: | 3.1.0.0 |
| Connectivity: | USB |
| PTDaemon Host System: | same as CCS |
| PTDaemon Host OS: | same as CCS |
| Setup Description: | The Temperature@lert-TM-STD30 used a 2 meters USB extension cable to connect to the controller. The Temperature@lert probe was placed in front of the main airflow inlet of the SUT less than 50mm. |
| Target Load | Voltage (V) | Current (A) | Avg Power Factor | Avg Active Power (W) | Power Measurement Uncertainty (%) | ||
|---|---|---|---|---|---|---|---|
| Avg | Range | Avg | Range | ||||
| Calibration 1 | 226 | 300.0 | 0.953 | 2.0 | 0.984 | 210 | 0.7% |
| Calibration 2 | 226 | 300.0 | 1.03 | 2.0 | 0.985 | 228 | 0.7% |
| Calibration 3 | 226 | 300.0 | 1.02 | 2.0 | 0.985 | 228 | 0.7% |
| 100% | 226 | 300.0 | 1.04 | 2.0 | 0.986 | 231 | 0.7% |
| 90% | 226 | 300.0 | 0.922 | 1.0 | 0.981 | 203 | 0.6% |
| 80% | 226 | 300.0 | 0.771 | 1.0 | 0.981 | 170 | 0.6% |
| 70% | 226 | 300.0 | 0.660 | 1.0 | 0.987 | 147 | 0.6% |
| 60% | 227 | 300.0 | 0.582 | 1.0 | 0.983 | 130 | 0.7% |
| 50% | 227 | 300.0 | 0.515 | 1.0 | 0.978 | 114 | 0.7% |
| 40% | 228 | 300.0 | 0.475 | 0.5 | 0.974 | 105 | 0.6% |
| 30% | 228 | 300.0 | 0.443 | 0.5 | 0.969 | 98.0 | 0.6% |
| 20% | 229 | 300.0 | 0.407 | 0.5 | 0.962 | 89.5 | 0.6% |
| 10% | 229 | 300.0 | 0.367 | 0.5 | 0.952 | 80.1 | 0.7% |
| Active Idle | 230 | 300.0 | 0.260 | 0.5 | 0.955 | 57.0 | 0.7% |