Dell Inc. PowerEdge R6515 (AMD EPYC 7702P, 2.00 GHz) SPECpower_ssj2008 = 18,463 overall ssj_ops/watt
Test Sponsor: Dell Inc. SPEC License #: 55 Test Method: Single Node
Tested By: Dell Inc. Test Location: Round Rock, TX, USA Test Date: Jul 22, 2020
Hardware Availability: Jul-2020 Software Availability: Feb-2020 Publication: Aug 12, 2020
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.8% 6,124,305 231 26,545
90% 90.0% 5,527,289 218 25,338
80% 79.9% 4,907,530 207 23,750
70% 69.9% 4,289,422 194 22,114
60% 60.0% 3,681,028 181 20,318
50% 49.8% 3,056,053 169 18,080
40% 40.1% 2,459,905 161 15,288
30% 30.0% 1,840,829 150 12,261
20% 19.9% 1,224,553 139 8,832
10% 10.0% 613,770 123 4,997
Active Idle 0 54.5 0
∑ssj_ops / ∑power = 18,463
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: PowerEdge R6515
Hardware
Hardware Vendor: Dell Inc.
Model: PowerEdge R6515 (AMD EPYC 7702P, 2.00 GHz)
Form Factor: 1U
CPU Name: AMD EPYC 7702P 2.00 GHz
CPU Characteristics: 64 core, 2.00 GHz, 256 MB L3 Cache, MaxBoost clock up to 3.35 GHz
CPU Frequency (MHz): 2000
CPU(s) Enabled: 64 cores, 1 chip, 64 cores/chip
Hardware Threads: 128 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 32 KB D on chip per core
Secondary Cache: 512 KB I+D on chip per core
Tertiary Cache: 256 MB I+D on chip per chip, 16 MB shared / 4 cores
Other Cache: None
Memory Amount (GB): 64
# and size of DIMM: 8 x 8 GB
Memory Details: 8GB 1Rx8 PC4-3200AA-R running at 2666. Slots A1-8 populated. (DPN 6VDNY)
Power Supply Quantity and Rating (W): 1 x 550
Power Supply Details: 550W Platinum Efficiency (DPN 6V43G)
Disk Drive: 1 x 240 GB M.2 SATA SSD
Disk Controller: PCIe attached Boot Optimized Storage (BOSS) card (DPN 5T20H)
# and type of Network Interface Cards (NICs) Installed: 1 x Dual-port Broadcom 5720
NICs Enabled in Firmware / OS / Connected: 2/2/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: High Performance power plan in OS (see SUT notes)
Operating System (OS): Microsoft Windows Server 2019 Datacenter
OS Version: 10.0.17763 Build 17763
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot 64-Bit Server VM (build 13.0.2+8, mixed mode, sharing), version 13.0.2
JVM Command-line Options: -server -Xmn1200m -Xms1400m -Xmx1400m -XX:MaxTenuringThreshold=1 -XX:ParallelGCThreads=2 -XX:InlineSmallCode=4000 -XX:MaxInlineSize=300 -XX:FreqInlineSize=3000 -XX:+UseParallelOldGC -XX:+UseLargePages
JVM Affinity: start /NODE[0-15] /AFFINITY [0xF, 0xF0]
JVM Instances: 32
JVM Initial Heap (MB): 1400
JVM Maximum Heap (MB): 1400
JVM Address Bits: 64
Boot Firmware Version: 1.4.8
Management Firmware Version: 4.10.10.10 A00
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: Microsoft Windows KB4532691
Boot Firmware Settings
Management Firmware Settings
none
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Dell Inc
Model: PowerEdge R410
CPU Description: Intel Xeon E5620, 2.40 GHz
Memory amount (GB): 32.0
Software
Operating System (OS): Microsoft Windows Server 2008 R2 Enterprise Edition Service Pack 1
JVM Vendor: Oracle Corporation
JVM Version: Hotspot(TM) Client VM, version 1.8.0_121
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation
Model: WT210
Serial Number: 91KA21977
Connectivity: RS-232
Input Connection: Default
Metrology Institute: NIST
Accredited by: TesCom
Calibration Label: T76421
Date of Calibration: 19-Jun-2020
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.9.1-a2d19f26-20190717
Setup Description: Connected to power supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 25 mm in front of SUT main airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 231 20.3
90% 218 20.3
80% 207 20.3
70% 194 20.3
60% 181 20.3
50% 169 20.3
40% 161 20.3
30% 150 20.3
20% 139 20.4
10% 123 20.3
Active Idle 54.5 20.3
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 20.3 255
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     6,118,464
Calibration 2     6,139,273
Calibration 3     6,137,368
ssj_ops@calibrated=6,138,321
100% 99.8% 6,138,321 6,124,305
90% 90.0% 5,524,488 5,527,289
80% 79.9% 4,910,656 4,907,530
70% 69.9% 4,296,824 4,289,422
60% 60.0% 3,682,992 3,681,028
50% 49.8% 3,069,160 3,056,053
40% 40.1% 2,455,328 2,459,905
30% 30.0% 1,841,496 1,840,829
20% 19.9% 1,227,664 1,224,553
10% 10.0% 613,832 613,770
Active Idle   0 0