SPECstorage™ Solution 2020_vda Result

Copyright © 2016-2025 Standard Performance Evaluation Corporation

New H3C Technologies Co., Ltd. SPECstorage Solution 2020_vda = 1000 Streams
H3C UniServer R3950 G7 Overall Response Time = 0.92 msec


Performance

Business
Metric
(Streams)
Average
Latency
(msec)
Streams
Ops/Sec
Streams
MB/Sec
1000.8811000459
2000.8982001921
3000.89830021382
4000.90040021842
5000.91950032304
6000.87260042764
7000.92970043225
8000.94080053686
9000.97690064142
10001.018100064608
Performance Graph


Product and Test Information

H3C UniServer R3950 G7
Tested byNew H3C Technologies Co., Ltd.
Hardware Available10/2024
Software Available1/2025
Date Tested2/2025
License Number9066
Licensee LocationsHangzhou,China

The H3C UniServer R3950G7 is 2U rackmount server powered by a AMD EPYC 5th generation 9355 processor. A single 9355 processor provides 32 cpu cores. When SMT is enabled via BIOS, it provides 64 cpu threads. This system is configured with 768GB mem and 13 2.5" local NVMe drives for the benchmark run.

Solution Under Test Bill of Materials

Item NoQtyTypeVendorModel/NameDescription
112U Rackmount serverNew H3C Technologies Co., Ltd.H3C UniServer R3950 G7This is a H3C 2U Rackmount server powered bya AMD EPYC 5th generation 9355 processor (32cores).This system supports 16 2.5" hot-swap NVMe drive bays. One drive was used for Ubuntu 24.04.1 OS and 12 drives were used for this performance testing.

Configuration Diagrams

  1. H3C UniServer R3950 G7

Component Software

Item NoComponentTypeName and VersionDescription
1SUTLinuxUbuntu 24.04.1 LTSOperating system for load generation and benchmark execution.

Hardware Configuration and Tuning - Physical

Component Name
Parameter NameValueDescription
N/AN/AN/A

Hardware Configuration and Tuning Notes

None

Software Configuration and Tuning - Physical

Component Name
Parameter NameValueDescription
N/AN/AN/A

Software Configuration and Tuning Notes

BIOS Settings: Simultaneous Multi Threading(SMT) was enabled to provide 64 cpu threads support.

Service SLA Notes

None

Storage and Filesystems

Item NoDescriptionData ProtectionStable StorageQty
1SSD Union UH832a,NVME,Gen5,6.4TB DisksRAID0Stable Storage12
2SSD NVMe OS DiskEXT4Stable Storage1
Number of Filesystems2
Total Capacity70 TiB
Filesystem TypeXFS(Test), EXT4(OS)

Filesystem Creation Notes

Software RAID0 was created by running mdadm command on the local 12 NVMe disks. Filesystem was created using mkfs.xfs command on the RAID0 device for benchmarking.

Storage and Filesystem Notes

The XFS filesystem was attached with a single mount and using the noatime option. All other mount options were the default for Ubuntu 24.04.1 LTS.

Transport Configuration - Physical

Item NoTransport TypeNumber of Ports UsedNotes
1N/AN/AN/A

Transport Configuration Notes

None

Switches - Physical

Item NoSwitch NameSwitch TypeTotal Port CountUsed Port CountNotes
1N/AN/AN/AN/AN/A

Processing Elements - Physical

Item NoQtyTypeLocationDescriptionProcessing Function
11CPUSUTAMD EPYC Gen5 9355RAID0, Storage functions

Processing Element Notes

None

Memory - Physical

DescriptionSize in GiBNumber of InstancesNonvolatileTotal GiB
2Rx4 PC5-6400B-R6412V768
Grand Total Memory Gibibytes768

Memory Notes

The system has 12 DIMM slots for DDR5 supports up to 6000 MT/s.

Stable Storage

The XFS file system provides journaling support for filesystem protection.

Solution Under Test Configuration Notes

The benchmark was run on a single H3C UniServer R3950 G7 server with local NVMe storage disks. RAID0 config was created using the drives and XFS filesystem was set up on the RAID0. Ubuntu 24.04.1 OS was installed on an internal NVMe drive. There were no additional external clients or storage devices or network devices were connected to this setup. The system has a AMD EPYC Gen5 9355 (32cores) processor and 12 NVMe drives were connected to support lots of disk storage and good storage performance. The testing was done with SMT enabled in BIOS, providing 64 cpu threads for more processing power.

Other Solution Notes

None

Dataflow

This single server setup has a RAID0 partition created on the local storage drives and XFS file system was created on the RAID. Data gets written directly on to the XFS filesystem and on to the NVMe storage devices. No other external storage device was used.

Other Notes

The benchmark was run on a single H3C UniServer R3950 G7 server using its local NVMe drives. No other client systems, or external storage devices or networking devices were connected to this test system. This benchmark was tested on Ubuntu 24.04.1 OS with kernel 6.8.0-41-generic. All components used for testing have applied security patches for Spectre and Meltdown vulnerabilities (CVE7-5754, CVE7-5753, CVE7-5715), ensuring that the system is protected from such attacks.

Other Report Notes

None


Generated on Sun Mar 9 22:37:40 2025 by SpecReport